OEM/ODM Manufacturer Laboratory Tables Used - Moisture Analyzer – Sateri
OEM/ODM Manufacturer Laboratory Tables Used - Moisture Analyzer – Sateri Detail:
| ST-100MW-T Series Moisture Analyzer | |
| Mode |
ST-100MW-T |
| Range (g) |
110g |
| Readability(g) |
0.001g |
| Operating Temp |
5℃-35℃ |
| Pan Size |
Ø 90mm |
| Heat Source |
Halogen Lamp |
| Temp.Sensor |
PT 100 |
| Temp. Range |
40℃-199℃ |
| Temp.Step |
1℃ |
| Moisture Range |
0.00%-100.00% |
| Moisture Readability |
0.01% |
| Dry Residual Range |
100.00%-0.00% |
| Dry Residual Readability |
0.01% |
| Temp Setting |
40℃-199℃ By 1℃ Step |
| Time Setting |
1-99min by 10 s |
| Number Of Storage |
20 |
| Number Of History |
20 |
| Heater |
220V ±15% 50HZ 400W |
| Balance |
Input: 220V 50HZ Output:9V |
|
|
|
| Host Dimension |
360X490X350mm |
| The Chamber Height |
22mm |
|
|
|
| Display |
5 inch touch panel |
| Calibration |
External Calibration |
| Interface |
RS232 |
Use halogen moisture analyzer should attention:
1,halogen moisture analyzer is used to measure the moisture content in the sample,
used for any other purpose are likely to cause harm and personal damage the instrument.
2, Please read the instructions carefully before you use it, do not use it under the environment
condition which not meet the requirements.
3, halogen rapid moisture analyzer only suit for professional operate.
4, halogen rapid moisture analyzer for power for the three plug with earthing socket,
banned disconnect apparatus grounding or use without a good grounding power supply.
5, Instrument around should ensure that there is enough space, so as to avoid heat accumulation and heat.
6, Please do not put flammable and explosive goods around the instrument.
7, After the test, the heating unit and the container is still very hot, so please do not touch it.
8, Toxic substances testing should be under ventilation environment
Product detail pictures:


Related Product Guide:
Shtayyeh government to focus on economy of resistance | Hpl Board For Lab
Secretlab Partners With Musician deadmau5 for Branded Gaming Chairs | Document Cabinet
We not only will try our best to offer excellent services to every customer, but also are ready to receive any suggestion offered by our customers for OEM/ODM Manufacturer Laboratory Tables Used - Moisture Analyzer – Sateri, The product will supply to all over the world, such as: Montreal , Poland , Tajikistan , We set "be a creditable practitioner to achieve the continuous development and innovation" as our motto. We would like to share our experience with friends at home and abroad, as a way to create a bigger cake with our joint efforts. We have several experienced R & D persons and we welcome OEM orders.
The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!